Induction Motor MCQs Part 7

Induction Motor MCQs Part 7

The speed of the rotating flux of a 3-phase, 4 pole induction motor having 50 Hz supply will be

The speed of the rotating flux of a 3-phase, 4 pole induction motor having 50 Hz supply will be:

  1. 1500 RPM
  2. 1000 RPM
  3. 750 RPM
  4. 3000 RPM

Correct answer: 1. 1500 RPM

Solution: Rotating flux Speed = 120*f/P = 120*50/4 = 1500 RPM

3-phase wound rotor motors are sometimes also referred as

3-phase wound rotor motors are sometimes also referred as:

  1. Synchronous
  2. Series
  3. Commutator
  4. Slip ring

Correct answer: 4. Slip ring

A wound rotor motor is used in practical applications that require

A wound rotor motor is used in practical applications that require:

  1. Less costly motor is not required
  2. High rotor resistance is required during
  3. High starting torque is required
  4. Speed control is required

Correct answer: 3. High starting torque is required

The maximum voltage is induced in the rotor of a 3-phase induction motor for which of following condition

The maximum voltage is induced in the rotor of a 3-phase induction motor for which of following condition:

  1. When it is blocked
  2. When it runs at no load
  3. When it runs at full load
  4. None of the above

Correct answer: 1. When it is blocked

Under running conditions, the maximum torque of a 3-phase induction motor is

Under running conditions, the maximum torque of a 3-phase induction motor is:

  1. Inversely proportional to supply voltage
  2. Directly proportional to rotor resistance
  3. Inversely proportional to rotor reactance at standstill
  4. None of the above

Correct answer: 3. Inversely proportional to rotor reactance at standstill

The approximate efficiency of a 3-phase induction motor running at slip s (in decimal) is given by

The approximate efficiency of a 3-phase induction motor running at slip s (in decimal) is given by:

  1. 1-s
  2. 1+s
  3. s-1
  4. s^2

Correct answer: 1. 1-s

Design Engineers manufacture 3 phase induction motor is such a way that under running conditions the rotor should have

Design Engineers manufacture 3 phase induction motor is such a way that under running conditions the rotor should have:

  1. High resistance
  2. High reactance
  3. Low resistance
  4. Large slip

Correct answer: 3. Low resistance

In a wound rotor motor, the rotor winding is wound for poles that are ________ that of stator winding

In a wound rotor motor, the rotor winding is wound for poles that are ________ that of stator winding:

  1. Greater than
  2. Small than
  3. Equal to 
  4. None of these

Correct answer: 3. Equal to

If a 3-phase, 4 pole, 50 Hz induction motor is at standstill position, what is value of rotor frequency

If a 3-phase, 4 pole, 50 Hz induction motor is at standstill position, what is value of rotor frequency:

  1. Zero
  2. 25 Hz
  3. 50 Hz
  4. Anywhere between 10 and 50 Hz

Correct answer: 3. 50 Hz

Solution: Speed of magnetic field = 120*f/P = 120*50/4 = 1500 RPM

Slip Speed = Speed of magnetic field – Mechanical shaft speed = 1500 – 0 = 1500

Slip = Slip speed/Speed of magnetic fields *100% = 1500/1500*100 = 100% = 1

Rotor frequency (f’) = sf = 1 * 50 Hz = 50 Hz

When an induction motor is running at full load, its rotor reactance is __________ rotor resistance

When an induction motor is running at full load, its rotor reactance is __________ rotor resistance:

  1. Comparable to
  2. Very large as compared to
  3. Large compared to
  4. Very small

Correct answer: 1. Comparable to

Leave a Reply